Brand Name : Merrytek
Model Number : MSA202S RC
Certification : CE, UKCA
Place of Origin : Shenzhen, China
MOQ : 100PCS
Price : Negotiation
Payment Terms : T/T
Supply Ability : 10000 pcs/month
Delivery Time : 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
Packaging Details : White box+ White box tags+ Clapboard+ Carton(K=A)
Working voltage : 220-240Vac 50Hz
Working mode : On/Off Function
Mounting height : 2.5-4.0m
Life time : 5 years warranty@Ta 230V full load
Load capacity : 400W (Inductive)
Working frequency : 24GHZ-24.25GHz
Breath detecting : yes
Mounting : Flush mounting or Surface mounting
24GHz Lifesnor Detecting AC Microwave Sensor Mounting Height 2.5 - 4.0m MSA202S RC
For more details, pls refer to the file as follows:
1. Parameters
| Working voltage | 220-240Vac 50Hz | 
| Power consumption | ≤1W | 
| Working mode | On/off | 
| Load capacity | 400W (LED,Flourescent,ballast) ; 800W (Incandescent,exhaust fan ) | 
| Max. Surge Capacity | 50A (50% Ipeak, twidth =500uS, 220Vac full load, cold start) | 
| MW sensor frequency | 24GHz-24.25GHz ISM band | 
| Transmitting power | 3dBm Max | 
| Detection angle | 100° | 
| Detection range (radius) | Normal motion: 3-4m ; Minor motion: 3-4m ; Breath signal: 2.5-3m | 
| Detection sensitivity | 25% 50% 75% 100% (by remote MH10 or dip switches) | 
| Hold time | 5s/30S /1min / 3min /5min /10min /20min (by remote MH10 ) 5s/30s/1min/3min/5min(by dip switches) | 
| Daylight sensor | 50Lux/Disable(by dip switches) 5Lux/15Lux/30Lux/50Lux/100Lux/150Lux/Disable (by remote MH10) | 
| Mounting height | 2.5-4.0m (typical) | 
| Installation | Recessed. Cut hole Φ55mm; 2) surface mount by bracket | 
| Wiring | Press-in Type Terminals, wire diameter: 0.75mm2-1.5mm2 | 
| Operating Temp. | 0℃...+50℃ | 
| Storage Temperature | -25℃...+80℃ | 
| Net weight | 49±3g | 
| Packing | Color box | 
| Life time | 5 years warranty@Ta 230V full load | 
2. Product Function
Walk Mode: a large movement (walking) of the human body.
Leisure Mode: only small motions of the human body, such as forward, backward, limb swing, head shaking, typing, playing with mobile phones, and other minor actions.
Presence Mode: only detects human breathing within the 30S (abdominal cavity, thoracic cavity expansion behavior actions), no significant movement is detected.
3. Dimension

4. Wiring Diagram

5. Structure

6. Start Process & Initialization
When powered on, the light will turn on for 20 seconds, The Sensor does not detect moving signals and remote control settings are invalid during initialization.
7. Factory settings
Detection Area: QS1 mode 100% Hold Time: 1min Daylight Sensor: Disable Indicator light: open
8. Installation Instruction


9. Application Notice
1) The sensor should be installed by a professional electrician. Please disconnect the power before installing, wiring, or changing the setting of the dial switch.
2) Put the sensor as far as possible from large areas of metal plate, glass, and other materials with high medium density to avoid triggering by mistake.
3) Avoid using objects that have been vibrating for a long time around the sensor, such as shaking fans, etc. The vibration signal will be regarded as the motion signal to trigger the sensor.
4) Avoid the detection window of the daylight sensor of the detector irradiated by an invalid light source, which will interfere with the measurement of ambient light.
5) The product should not be too close to the wireless router at least more than 0.5m apart, when it is installed and used.
6) Setting detecting area and indicator on-off by MH10.(Pressing HS in MH10 makes indicator on and pressing LS in MH10 makes indicator off.)
7) The microwave can penetrate the wall of the building. It may cause misreport when a microwave penetrates the wall to detect moving objects outside the fortified area. To avoid triggering by mistake, choose a suitable place when installing, keep away from glass, plasterboard, wooden walls, and other things that the microwave can easily penetrate, and choose appropriate sensing parameters according to space, for example:
A. When the product is used in a room whose length and width is about 2m or less, the detecting area should be set to 25% (application scenario: washroom, sitting room )
B. When the product is used in a room whose length and width is about 3m, the detecting area should be set to 50% (application scenario: washroom, hallway, sitting room )
C. When the product is used in a room whose length and width is about 4m, the detecting area should be set to 75% (application scenario: small office, meeting room, library )
D. When the product is used in a room whose length and width are about 5m or more, the detecting area should be set to 100% (application scenario: large office, meeting room, library )
Note: The setting detecting area depends on the actual environment (detecting area parameters above the application scenario are for reference only).
8) Hold time setting: space of one person: 1-3 minutes, space of more than one person: 30 seconds to 1 minute. It is not recommended to set a hold time of more than 5 minutes, to avoid the small motion signal in the space from interfering with the hold-time closing.
10. DIPs settings

11. Remote Control

|   | 
| 24GHz Lifesnor Detecting AC Microwave Sensor Mounting Height 2.5 - 4.0m MSA202S RC Images | 
 24GHz Lifesnor Detection DC Microwave Sensor Embedded Type Dry Contact Version
                                                                                    
                        
                        
                        
                                                            24GHz Lifesnor Detection DC Microwave Sensor Embedded Type Dry Contact Version
                                                    
                        
                     MSA211 B 24GHz Large-Space Presence Motion Sensor With Casambi Bluetooth For
                                                                                    
                        
                        
                        
                                                            MSA211 B 24GHz Large-Space Presence Motion Sensor With Casambi Bluetooth For
                                                    
                        
                     Waterproof Two - Output Microwave Occupancy Sensors For Lighting IP20
                                                                                    
                        
                        
                        
                                                            Waterproof Two - Output Microwave Occupancy Sensors For Lighting IP20
                                                    
                        
                     Downlight Microwave Motion Sensor , Outdoor Flush Mount Ceiling Light Motion
                                                                                    
                        
                        
                        
                                                            Downlight Microwave Motion Sensor , Outdoor Flush Mount Ceiling Light Motion
                                                    
                        
                     Breathing Detecting ceiling mounted occupancy sensor Dry Contact Output MSA021D
                                                                                        
                                                        
                        
                        
                        
                                                            Breathing Detecting ceiling mounted occupancy sensor Dry Contact Output MSA021D
                                                    
                        
                     5.8G Lifebeing Sensor Breathing Detecting ON OFF Function 220-240v AC Input
                                                                                        
                                                        
                        
                        
                        
                                                            5.8G Lifebeing Sensor Breathing Detecting ON OFF Function 220-240v AC Input
                                                    
                        
                     Recessed Mounting 24GHz LifeBeing Sensor Built In Tuya ZigBee Wireless Module
                                                                                    
                        
                        
                        
                                                            Recessed Mounting 24GHz LifeBeing Sensor Built In Tuya ZigBee Wireless Module
                                                    
                        
                     24GHz Lifebeing Detection DC Microwave Sensor Dry Contact Version MSA200D RC
                                                                                    
                        
                        
                        
                                                            24GHz Lifebeing Detection DC Microwave Sensor Dry Contact Version MSA200D RC
                                                    
                        
                     Recessed Mounted 24GHz Lifesnor Sensor Built In Tuya ZigBee Wireless Module
                                                                                    
                        
                        
                        
                                                            Recessed Mounted 24GHz Lifesnor Sensor Built In Tuya ZigBee Wireless Module
                                                    
                        
                     24GHz FMCW MmWave Radar Sensors Standalone Microwave Presence Detectors
                                                                                    
                        
                        
                        
                                                            24GHz FMCW MmWave Radar Sensors Standalone Microwave Presence Detectors